For more information contact us at (818) 407-3400
For more information contact us at (818) 407-3400

Air Driven Gas Boosters Catalog

Single Acting

Approximate Stall Point: Maximum Safe Pressure PSI (BAR) Volume Displacement Per Cycle
Model
( Area Ratio x
Drive Air PSI
) + ( Assist Factor x
Gas Inlet PSI
)
Outlet Inlet IN3 (CM3)
5G-SS-7 7 x Drive Air (No assist from gas inlet) 2500 (172) 2500 (172) 13.2 (216)
5G-SS-14 14 x Drive Air (No assist from gas inlet) 4500 (310) 4500 (310) 7.0 (115)
5G-SS-30 30 x Drive Air (No assist from gas inlet) 9000 (621) 9000 (621) 3.1 (51)
5G-SS-50 50 x Drive Air (No assist from gas inlet) 15000 (1034) 15000 (1034) 1.76 (29)
5G-SS-75 75 x Drive Air (No assist from gas inlet) 30000 (2068) 30000 (2068) 1.2 (20)
5G-SD-60 60 x Drive Air (No assist from gas inlet) 9000 (621) 9000 (621) 3.1 (51)
5G-SD-100 100 x Drive Air (No assist from gas inlet) 15000 (1034) 15000 (1034) 1.76 (29)
5G-SD-150 150 x Drive Air (No assist from gas inlet) 30000 (2068) 30000 (2068) 1.2 (20)

Double Acting

Approximate Stall Point: Maximum Safe Pressure PSI (BAR) Volume Displacement Per Cycle
Model
( Area Ratio x
Drive Air PSI
) + ( Assist Factor x
Gas Inlet PSI
)
Outlet Inlet IN3 (CM3)
5G-DS-4 (4 x Drive Air) + (1.00 x Gas Inlet) 1250 (86) 1250 (86) 24.1 (395)
5G-DS-7 (7 x Drive Air) + (1.00 x Gas Inlet) 2500 (172) 2500 (172) 26.4 (433)
5G-DS-14 (14 x Drive Air) + (1.00 x Gas Inlet) 4500 (310) 4500 (310) 14 (229)
5G-DS-30 (30 x Drive Air) + (1.00 x Gas Inlet) 9000 (621) 9000 (621) 6.2 (102)
5G-DS-50 (50 x Drive Air) + (1.00 x Gas Inlet) 15000 (1034) 15000 (1034) 3.52 (58)
5G-DS-75 (75 x Drive Air) + (1.00 x Gas Inlet) 30000 (2068) 30000 (2068) 2.4 (39)
5G-DD-14 (14 x Drive Air) + (1.00 x Gas Inlet) 2500 (172) 2500 (172) 26.4 (433)
5G-DD-28 (28 x Drive Air) + (1.00 x Gas Inlet) 4500 (310) 4500 (310) 14 (229)
5G-DD-60 (60 x Drive Air) + (1.00 x Gas Inlet) 9000 (621) 9000 (621) 6.2 (102)
5G-DD-100 (100 x Drive Air) + (1.00 x Gas Inlet) 15000 (1034) 15000 (1034) 3.52 (58)
5G-DD-150 (150 x Drive Air) + (1.00 x Gas Inlet) 30000 (2068) 30000 (2068) 2.4 (39)

Two Stage

Approximate Stall Point: Maximum Safe Pressure PSI (BAR) Volume Displacement Per Cycle
Model
( Area Ratio x
Drive Air PSI
) + ( Assist Factor x
Gas Inlet PSI
)
Outlet Inlet IN3 (CM3)
5G-TS-4 (4 x Drive Air) + (1.00 x Gas Inlet) 1250 (86) 1250 (86) 12 (197)
5G-TS-7/14 (14 x Drive Air) + (2.00 x Gas Inlet) (b,c) 4500 (310) 2500 (172) 13.2 (216)
5G-TS-7/30 (30 x Drive Air) + (4.29 x Gas Inlet) (b,c) 9000 (621) 2500 (172) 13.2 (216)
5G-TS-7/50 (50 x Drive Air) + (7.14 x Gas Inlet) (b,c) 15000 (1034) 2500 (172) 13.2 (216)
5G-TS-14/30 (30 x Drive Air) + (2.14 x Gas Inlet) (b,c) 9000 (621) 4500 (310) 7 (115)
5G-TS-14/50 (50 x Drive Air) + (3.57 x Gas Inlet) 15000 (1034) 2500 (172) 7 (115)
5G-TS-14/75 (75 x Drive Air) + (5.36 x Gas Inlet) (b,c) 30000 (2068) 4500 (310) 7 (115)
5G-TS-30/50 (50 x Drive Air) + (1.66 x Gas Inlet) (b,c) 15000 (1034) 9000 (621) 3.1 (51)
5G-TS-30/75 (75 x Drive Air) + (2.50 x Gas Inlet) (b,c) 30000 (2068) 9000 (621) 3.1 (51)
5G-TS-30/92 (92 x Drive Air) + (3.06 x Gas Inlet) (b,c) 30000 (2068) 9000 (621) 3.1 (51)
5G-TS-50/92 (92 x Drive Air) + (1.84 x Gas Inlet) (b,c) 30000 (2068) 15000 (1034) 1.76 (29)
5G-TD-14/28 (28 x Drive Air) + (2.0 x Gas Inlet) (b,c) 4500 (310) 2500 (172) 13.2 (216)
5G-TD-14/60 (60 x Drive Air) + (4.28 x Gas Inlet) (b,c) 9000 (621) 2500 (172) 13.2 (216)
5G-TD-28/60 (60 x Drive Air) + (2.14 x Gas Inlet) (b,c) 9000 (621) 4500 (310) 7 (115)
5G-TD-28/100 (100 x Drive Air) + (3.57 x Gas Inlet) (b,c) 15000 (1034) 4500 (310) 7 (115)
5G-TD-28/150 (150 x Drive Air) + (5.36 x Gas Inlet) (b,c) 30000 (2068) 4500 (310) 7 (115)
5G-TD-60/100 (100 x Drive Air) + (1.66 x Gas Inlet) (b,c) 15000 (1034) 9000 (621) 3.1 (51)
5G-TD-60/150 (150 x Drive Air) + (2.50 x Gas Inlet) (b,c) 30000 (2068) 9000 (621) 3.1 (51)